earthkit.meteo.thermo.xarray.wet_bulb_temperature_from_dewpoint¶
- earthkit.meteo.thermo.xarray.wet_bulb_temperature_from_dewpoint(t, td, p, ept_method='ifs', t_method='bisect')¶
Compute the pseudo adiabatic wet bulb temperature from dewpoint.
- Parameters:
t (
xarray.DataArray) – Temperature (K)td (
xarray.DataArray) – Dewpoint (K)p (
xarray.DataArray) – Pressure (Pa)ept_method (
str, optional) – Specifies the computation method for the equivalent potential temperature. The possible values are: “ifs”, “bolton35”, “bolton39”. (Seeept_from_dewpoint()for details.)t_method (
str, optional) –Specifies the method to find the temperature along the moist adiabat defined by the equivalent potential temperature. The possible values are as follows:
”bisect”:
temperature_on_moist_adiabat()witht_method= “bisect” is used”newton”:
temperature_on_moist_adiabat()witht_method= “newton” is used
- Returns:
Wet bulb temperature (K)
- Return type:
xarray.DataArray
The computation is based on Normand’s rule [Wallace2006] (Chapter 3.5.6):
first the equivalent potential temperature is computed with the given
ept_method(usingept_from_dewpoint()). This defines the moist adiabat.then the wet bulb potential temperature is determined as the temperature at pressure
pon the moist adiabat with the givent_method.